{"id":3255,"date":"2004-01-01T00:00:00","date_gmt":"2003-12-31T23:00:00","guid":{"rendered":"https:\/\/www.ardentis.ch\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/"},"modified":"2026-07-01T10:56:16","modified_gmt":"2026-07-01T08:56:16","slug":"implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during","status":"publish","type":"publication","link":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/","title":{"rendered":"Implant stability measurement of delayed and immediately loaded implants during healing"},"content":{"rendered":"<p><strong>Original Language:<\/strong>\u00a0EN<\/p>\n<p><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/15355394\/\"><strong data-start=\"80\" data-end=\"102\">Publication Access<\/strong><\/a><\/p>\n<p><strong>Abstract<\/strong><\/p>\n<p>The purpose of the present study was (1) to measure the primary stability of ITI implants placed in both jaws and determine the factors that affect the implant stability quotient (ISQ) determined by the resonance frequency method and (2) to monitor implant stability during the first 3 months of healing and evaluate any difference between immediately loaded (IL) implants and standard delayed loaded (DL) implants. The IL and DL groups consisted of 18 patients\/63 implants and 18 patients\/43 implants. IL implants were loaded after 2 days; DL implants were left to heal according to the one-stage procedure.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Original Language:\u00a0EN Publication Access Abstract The purpose of the present study was (1) to measure the primary stability of ITI implants placed in both jaws and determine the factors that affect the implant stability quotient (ISQ) determined by the resonance frequency method and (2) to monitor implant stability during the first 3 months of healing [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":5220,"template":"","meta":{"video_url":"","sticky":false,"authors":"Bischof M., Nedir R., Szmukler-Moncler S., Bernard J-P., Samson J.","journal":"Clinical Oral Implants Research 15:529-539, 2004"},"publication_tag":[],"class_list":["post-3255","publication","type-publication","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Implant stability measurement of delayed | Ardentis<\/title>\n<meta name=\"description\" content=\"Implant stability measurement of delayed and immediately loaded implants during healing. A clinical RFA study with SLA ITI implants.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Implant stability measurement of delayed | Ardentis\" \/>\n<meta property=\"og:description\" content=\"Implant stability measurement of delayed and immediately loaded implants during healing. A clinical RFA study with SLA ITI implants.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/\" \/>\n<meta property=\"og:site_name\" content=\"Ardentis\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-01T08:56:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ardentis.ch\/wp-content\/uploads\/2004\/01\/AP_00905-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1707\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"ScholarlyArticle\",\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/\"},\"author\":{\"name\":\"Ardentis\",\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/#\\\/schema\\\/person\\\/39940dbfaeb088f7342e9d0700090516\"},\"headline\":\"Implant stability measurement of delayed and immediately loaded implants during healing\",\"datePublished\":\"2003-12-31T23:00:00+00:00\",\"dateModified\":\"2026-07-01T08:56:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/\"},\"wordCount\":108,\"publisher\":{\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.ardentis.ch\\\/wp-content\\\/uploads\\\/2004\\\/01\\\/AP_00905-scaled.jpg\",\"inLanguage\":\"en-US\"},{\"@type\":[\"WebPage\",\"MedicalWebPage\"],\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/\",\"url\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/\",\"name\":\"Implant stability measurement of delayed | Ardentis\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.ardentis.ch\\\/wp-content\\\/uploads\\\/2004\\\/01\\\/AP_00905-scaled.jpg\",\"datePublished\":\"2003-12-31T23:00:00+00:00\",\"dateModified\":\"2026-07-01T08:56:16+00:00\",\"description\":\"Implant stability measurement of delayed and immediately loaded implants during healing. A clinical RFA study with SLA ITI implants.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.ardentis.ch\\\/wp-content\\\/uploads\\\/2004\\\/01\\\/AP_00905-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/www.ardentis.ch\\\/wp-content\\\/uploads\\\/2004\\\/01\\\/AP_00905-scaled.jpg\",\"width\":2560,\"height\":1707,\"caption\":\"A person reviewing dental X-ray images in a clinical environment, emphasizing advanced dental technology.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/publications\\\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Implant stability measurement of delayed and immediately loaded implants during healing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/\",\"name\":\"Ardentis\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/#organization\",\"name\":\"Ardentis\",\"url\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.ardentis.ch\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/logo.svg\",\"contentUrl\":\"https:\\\/\\\/www.ardentis.ch\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/logo.svg\",\"width\":154,\"height\":40,\"caption\":\"Ardentis\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/en\\\/#\\\/schema\\\/person\\\/39940dbfaeb088f7342e9d0700090516\",\"name\":\"Ardentis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.ardentis.ch\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Avatar-site-2-96x96.jpg\",\"url\":\"https:\\\/\\\/www.ardentis.ch\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Avatar-site-2-96x96.jpg\",\"contentUrl\":\"https:\\\/\\\/www.ardentis.ch\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Avatar-site-2-96x96.jpg\",\"caption\":\"Ardentis\"},\"url\":\"https:\\\/\\\/www.ardentis.ch\\\/en\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Implant stability measurement of delayed | Ardentis","description":"Implant stability measurement of delayed and immediately loaded implants during healing. A clinical RFA study with SLA ITI implants.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/","og_locale":"en_US","og_type":"article","og_title":"Implant stability measurement of delayed | Ardentis","og_description":"Implant stability measurement of delayed and immediately loaded implants during healing. A clinical RFA study with SLA ITI implants.","og_url":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/","og_site_name":"Ardentis","article_modified_time":"2026-07-01T08:56:16+00:00","og_image":[{"width":2560,"height":1707,"url":"https:\/\/www.ardentis.ch\/wp-content\/uploads\/2004\/01\/AP_00905-scaled.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"ScholarlyArticle","@id":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/#article","isPartOf":{"@id":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/"},"author":{"name":"Ardentis","@id":"https:\/\/www.ardentis.ch\/en\/#\/schema\/person\/39940dbfaeb088f7342e9d0700090516"},"headline":"Implant stability measurement of delayed and immediately loaded implants during healing","datePublished":"2003-12-31T23:00:00+00:00","dateModified":"2026-07-01T08:56:16+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/"},"wordCount":108,"publisher":{"@id":"https:\/\/www.ardentis.ch\/en\/#organization"},"image":{"@id":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ardentis.ch\/wp-content\/uploads\/2004\/01\/AP_00905-scaled.jpg","inLanguage":"en-US"},{"@type":["WebPage","MedicalWebPage"],"@id":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/","url":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/","name":"Implant stability measurement of delayed | Ardentis","isPartOf":{"@id":"https:\/\/www.ardentis.ch\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/#primaryimage"},"image":{"@id":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ardentis.ch\/wp-content\/uploads\/2004\/01\/AP_00905-scaled.jpg","datePublished":"2003-12-31T23:00:00+00:00","dateModified":"2026-07-01T08:56:16+00:00","description":"Implant stability measurement of delayed and immediately loaded implants during healing. A clinical RFA study with SLA ITI implants.","breadcrumb":{"@id":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/#primaryimage","url":"https:\/\/www.ardentis.ch\/wp-content\/uploads\/2004\/01\/AP_00905-scaled.jpg","contentUrl":"https:\/\/www.ardentis.ch\/wp-content\/uploads\/2004\/01\/AP_00905-scaled.jpg","width":2560,"height":1707,"caption":"A person reviewing dental X-ray images in a clinical environment, emphasizing advanced dental technology."},{"@type":"BreadcrumbList","@id":"https:\/\/www.ardentis.ch\/en\/publications\/implant-stability-measurement-of-delayed-and-immediately-loaded-implants-during\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.ardentis.ch\/en\/"},{"@type":"ListItem","position":2,"name":"Implant stability measurement of delayed and immediately loaded implants during healing"}]},{"@type":"WebSite","@id":"https:\/\/www.ardentis.ch\/en\/#website","url":"https:\/\/www.ardentis.ch\/en\/","name":"Ardentis","description":"","publisher":{"@id":"https:\/\/www.ardentis.ch\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ardentis.ch\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.ardentis.ch\/en\/#organization","name":"Ardentis","url":"https:\/\/www.ardentis.ch\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ardentis.ch\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ardentis.ch\/wp-content\/uploads\/2025\/07\/logo.svg","contentUrl":"https:\/\/www.ardentis.ch\/wp-content\/uploads\/2025\/07\/logo.svg","width":154,"height":40,"caption":"Ardentis"},"image":{"@id":"https:\/\/www.ardentis.ch\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.ardentis.ch\/en\/#\/schema\/person\/39940dbfaeb088f7342e9d0700090516","name":"Ardentis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ardentis.ch\/wp-content\/uploads\/2026\/03\/Avatar-site-2-96x96.jpg","url":"https:\/\/www.ardentis.ch\/wp-content\/uploads\/2026\/03\/Avatar-site-2-96x96.jpg","contentUrl":"https:\/\/www.ardentis.ch\/wp-content\/uploads\/2026\/03\/Avatar-site-2-96x96.jpg","caption":"Ardentis"},"url":"https:\/\/www.ardentis.ch\/en"}]}},"_links":{"self":[{"href":"https:\/\/www.ardentis.ch\/en\/wp-json\/wp\/v2\/publication\/3255","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ardentis.ch\/en\/wp-json\/wp\/v2\/publication"}],"about":[{"href":"https:\/\/www.ardentis.ch\/en\/wp-json\/wp\/v2\/types\/publication"}],"author":[{"embeddable":true,"href":"https:\/\/www.ardentis.ch\/en\/wp-json\/wp\/v2\/users\/2"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ardentis.ch\/en\/wp-json\/wp\/v2\/media\/5220"}],"wp:attachment":[{"href":"https:\/\/www.ardentis.ch\/en\/wp-json\/wp\/v2\/media?parent=3255"}],"wp:term":[{"taxonomy":"publication_tag","embeddable":true,"href":"https:\/\/www.ardentis.ch\/en\/wp-json\/wp\/v2\/publication_tag?post=3255"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}